Blog Post Promotion

Water Quality Online Monitoring Products

КатегоријаУ резервоару 76 0

【Product Recommendation】

Water Quality Online Monitoring Products

 

The Zwinsoft water quality monitoring system is a comprehensive online automatic monitoring system that utilizes online automatic analysis instruments. It incorporates sensor technology, automatic measurement technology, automatic control technology, computer application technology, and related specialized analysis software and communication networks.

ZWIN-WQMS06 Water Quality Multi-Parameter Smart Online mini Station

ZWIN-WQMS06 water quality multi-parameter intelligent online mini station is an online water quality monitoring system that integrates water sampling unit, pretreatment and water distribution unit, detection and analysis unit, automatic control unit, data acquisition and transmission control unit, remote monitoring unit and auxiliary unit.

Product Composition

  1. Water sampling unit

The main function of the water sampling unit is to ensure that the water samples at the water sampling point are led to the monitoring system instrument room under any circumstances and meet the needs of the drainage unit and analytical instruments. The water sampling unit generally includes water sampling structures, water sampling pumps, water sampling pipelines, cleaning equipment and insulation equipment. The water sampling system adopts dual-circuit water sampling, and the running status of the water pump can be controlled by the program. It can also protect itself in the event of a power outage and automatically recover when the power is on again.

  1. Pretreatment and water distribution unit

The system settles the raw water according to the suspended matter situation of the on-site water sample, and then passes the still water sample through a high-precision filter element for precise filtration. The filtered water sample is then provided to the instrument for analysis and testing.

  1. Detection and analysis unit

The automatic water quality analysis unit is the core part of the fixed water quality monitoring system, which is composed of automatic detection instruments that meet the requirements of various detection items. The selection principle of the instrument type is that the instrument measurement range meets the water quality analysis requirements, and the measurement results are consistent with the standard method; the instrument structure is reasonable and the performance is stable; the operating cost is reasonable, the maintenance is small, and the maintenance cost is low; and there is less secondary pollution.

  1. Automatic control unit

The system control unit is composed of base station control software and industrial control computer hardware. It is used to sense changes in signals from online detection instruments and equipment, and send relevant control commands, including: water intake unit control, instrument operation control, instrument data acquisition and storage, video acquisition and transmission, real-time water quality analysis statistics and upload, remote communication, process scheduling, etc., to ensure continuous, reliable and safe operation of the system.

5.Data collection and transmission unit

The data acquisition and transmission unit mainly realizes the functions of monitoring the on-site operation status, setting the on-site operation parameters, storing the historical data and system operation log, communicating with the host computer, etc. It also has the data storage capability.

 

Technical Parameters

Working temperature: -10℃~55℃;

Working relative humidity: (0~90)%RH (no condensation);

Power supply voltage: AC 220V±22V 50Hz

Power: 5000W

Total weight of nine-parameter cabinet: about 800kg

Analytical unit (4 instruments): about 40kg/unit

Range:

CODCr : (0~1500) mg/L ; resolution 0.001 mg/L

Ammonia nitrogen : (0.05~1500) mg/L ; resolution 0.001 mg/L

Total phosphorus : (0~100) mg/L ; resolution 0.001 mg/L

Total nitrogen : (0~300) mg/L ; resolution 0.001 mg/L

pH : (0~14) ; resolution 0.01 pH

Dissolved oxygen : (0~20) mg/L ; resolution 0.01 mg/L

Conductivity : (0~200000) uS/cm ; resolution 0.1 uS/cm

Turbidity : (0~4000) NTU ; resolution 0.01 NTU

Temperature : (0~55) ℃ ; resolution 0.1 ℃

 

Basic skills

  1. Integrated design modularization, flexible expansion of environmental state parameters, and flexible configuration of processes;
  2. According to national standards, expand the data collection and transmission content that meets actual needs, achieve interconnection and interoperability, and feedback the system operation status;
  3. Flexibly configure water collection and distribution methods according to the on-site environment;
  4. A variety of water sample pretreatment modes can be used together to meet the needs of instrument analysis and testing;
  5. The system supports real-time data upload function;
  6. The system supports remote data collection, standard solution verification, and sample retention for exceeding the standard;
  7. It has a variety of flexible operation modes such as intelligent identification of abnormal data and excessive data;

 

 

ZWIN-TPN1006 Total Phosphorus and Total Nitrogen Two-in-One Online Automatic Monitoring

The two-in-one online automatic monitoring instrument for total phosphorus and total nitrogen is mainly used to monitor phosphorus-containing compounds in the form of various phosphates in water and nitrogen-containing chemicals in various forms in water. The automatic monitoring instrument is widely used in sewage monitoring points, surface water monitoring stations, river sections and drinking water source monitoring stations.

Technical Parameters

Measuring range: Total phosphorus 0~80mg/L Total nitrogen 0~160mg/L (customizable)

Monitoring switch: The total phosphorus and total nitrogen can be switched manually or automatically.

Indication error: ≤±5% or ≤±0.005mg/L, whichever is greater

Repeatability: ≤5%

Resolution: 0.001mg/L

Display: 7-inch touch screen

 

Features

  1. The sapphire valve used for core collection is a ten-way valve with high wear resistance, strong acid and alkali resistance, organic solvent resistance, long service life and high stability;
  2. Using a specially designed reference method, slight displacement and slight pollution of the digestion pool will not affect the measurement value;
  3. It has the function of waste liquid separation, which can realize the separate discharge of high-concentration reaction waste liquid and low-concentration cleaning waste liquid;
  4. It has dynamic dilution function, which can automatically adjust the dilution multiple according to the range set on site;
  5. It has built-in quality control functions such as spike recovery, blank test, standard sample verification, zero point verification, span verification, parallel sample test, etc., and can realize automatic, manual, remote and other ways to start the quality control function;
  6. It has the functions of automatic fault diagnosis and abnormal information upload and recording, such as component failure, over-range alarm, over-standard alarm, reagent shortage alarm, etc.;
  7. With overheat protection: if the heating temperature is too high, the heater will automatically cut off the power;
  8. After abnormal reset and power failure, the instrument will automatically discharge the residual reactants in the instrument and automatically restore to the initial working state. It has a power-on alarm function, and the instrument will generate an alarm message when it is powered on again after power failure;
  9. It has the function of recording the process log of the analytical instrument, measuring data and alarm information. It records the data once every hour and can store data for more than 3 years. It can also export data quickly via USB flash drive.

 

ZWIN-TP1006 Total Phosphorus Water Quality Online Automatic Monitoring

The main purpose of the automatic total phosphorus monitoring is to monitor phosphorus-containing compounds in the form of various phosphates in water. They are divided into orthophosphates, condensed phosphates (pyrophosphates, metaphosphates and polyphosphates) and organically bound phosphorus (such as phospholipids, etc.). They are widely used in sewage monitoring points, surface water monitoring stations, river sections and drinking water source monitoring stations.

ZWIN-TN1006 Total Nitrogen Water Quality Online Automatic Monitoring

The main purpose of the total nitrogen automatic monitoring is to monitor nitrogen compounds in various forms in water. In natural water and wastewater, nitrogen almost always exists in the form of various nitrates, which are divided into nitrate nitrogen, nitrite nitrogen, ammonia nitrogen and organic nitrogen (protein, amino acid, etc.). They exist in the water environment and are the main indicators of eutrophication of water bodies. The total nitrogen automatic monitor is widely used in sewage monitoring points, surface water monitoring stations, river sections and drinking water source monitoring stations.

ОзнакеКвалитет воде Следећи чланак:
Кликните за отказивање одговора
    展开更多
    Онлајн консултације

    loading...